On this page
The lights go out during dinner, the fridge hums to a stop, and the house goes quiet. Generator size for house comes down to the running watts of everything you want to power at the same time, plus the starting watts the largest motor in the house needs when it kicks on. Get those figures right and the generator keeps the essentials running through the outage, and getting them wrong means it trips or stalls when the load peaks.
SolarKitHQ earns a commission when you buy through links on this page, at no extra cost to you. As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure.
Generator size for house: the quick answer
Add up the running watts of every load you want to power at the same time, then add the starting watts of the largest motor among them. A generator rated at 8,000 running watts and 10,000 starting watts covers a common house load list: the maker lists central AC, well pumps, refrigerators, sump pumps, lights and essential appliances running at the same time on that rating. If the list is longer, size up; if the list is shorter, a smaller rating may cover it. The rest of this guide shows how to work out the figures for a house and what to check before buying.
| Figure | Generac GP8000E rating |
|---|---|
| Running watts | 8,000 |
| Starting watts | 10,000 |
| Runtime | Up to 10 hours at 50% load, or 15 hours at 25% load |
| Fuel tank | 7.9 gallons |
How to work out the size
Start with a list of the loads the house must keep running through an outage. Central AC, a well pump, the refrigerator, a sump pump, lights and the essential appliances are the loads the maker names for an 8,000 running watt unit, and the list for a house starts there. A watt meter on a load shows what it draws while it runs, and the nameplate on a motor gives its rated draw. Add the running watts of the loads that run together, and keep the starting watts of the largest motor separate, since a motor draws far more at startup than while it runs. See the generator wattage calculator to work through the loads for a house.
Running watts and starting watts
Running watts are what a load draws while it runs. Starting watts are the short spike a motor draws when it starts, and the spike runs higher than the running draw. A generator lists the two figures separately, and the starting figure is the one that trips a generator that is sized only for the running load.
The Generac GP8000E lists 8,000 running watts and 10,000 starting watts. PowerRush Technology adds over 30% more starting capacity, which the maker says lets large appliances, HVAC systems and power tools start without tripping. That extra starting capacity matters most for motor loads such as central AC and well pumps, which draw a heavy spike when they start.
Outlets, runtime and fuel
The unit has two 120V 20A GFCI duplex outlets and one 120/240V 30A locking receptacle, with circuit-breaker protection and GFCI safety. The outlets decide what plugs in directly: the 120V outlets take the usual household loads, and the 120/240V receptacle takes the heavier connection.
The 420cc OHV engine runs from a 7.9-gallon steel fuel tank with a built-in fuel gauge. The maker lists up to 10 hours of continuous power at 50% load or 15 hours at 25% load. Push-button electric start with a plug-in battery jack starts the unit from the included 12V lead-acid battery, and a recoil pull-start backup is included for manual use. The maker backs the unit with a 3-year residential limited warranty.
At 112 pounds, the unit moves on 9.5-inch never-flat wheels with a fold-down locking handle, inside a 1.25-inch steel tube cradle. The weight and wheels matter when the generator has to cross grass, gravel or uneven ground to reach its spot.
Place it outdoors, far from doors and windows
Fuel generators run outdoors only, far from doors and windows, because of carbon monoxide. COsense Technology monitors carbon monoxide levels and shuts the generator down automatically when dangerous CO concentrations are detected, which the maker says protects everyone nearby. If the generator connects to the house wiring, a licensed electrician should install it.
Ways to make the runtime last longer
- Run only the loads the house needs, and switch off the rest; a lighter load stretches the tank, since the maker lists 15 hours at 25% load against 10 hours at 50% load.
- Check the built-in fuel gauge before the tank runs low, and keep fuel on hand for a long outage.
- Start the largest motor first, then add the smaller loads, so the starting spike does not land on top of a full running load.
- For a longer outage, plan the refuel around the runtime the maker lists, and let the unit cool before refuelling.
See the guide to how long a gas generator runs on one tank for more on runtime.
FAQ: power away from the grid
What size generator does a house need?
Add the running watts of the loads that run together, then add the starting watts of the largest motor. A unit rated at 8,000 running watts and 10,000 starting watts covers central AC, well pumps, refrigerators, sump pumps, lights and essential appliances at the same time, according to the maker.
What is the difference between running watts and starting watts?
Running watts are what a load draws while it runs, and starting watts are the short spike a motor draws when it starts. The Generac GP8000E lists 8,000 running watts and 10,000 starting watts, and PowerRush adds over 30% more starting capacity for motor loads.
How long will a generator run on a tank of fuel?
The maker lists up to 10 hours at 50% load or 15 hours at 25% load from the 7.9-gallon tank, so the runtime depends on how heavily the unit is loaded.
Can a portable generator power central air conditioning?
The maker lists central AC among the loads an 8,000 running watt unit powers at the same time as well pumps, refrigerators, sump pumps, lights and essential appliances. Check the starting watts the AC needs against the 10,000 starting watt rating before buying.
Where should a portable generator run?
Outdoors only, far from doors and windows, because of carbon monoxide. The Generac unit has COsense Technology, which shuts the generator down automatically when dangerous CO concentrations are detected.
Related solar guides
See every Generators guide, the generator wattage calculator, the guide to how long a gas generator runs on one tank, the gas generator vs inverter generator comparison and the best large inverter generators for a house.